Ağırlık:
Max. 35 kg
Akış Hızı:
100 - 300 mL/min
Analog çıkışlar:
Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard 4, optional: 8
Boyut (Y x G x D):
688 mm x 460 mm x 340 mm
Çıkış:
Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Cihaz havası:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Demineralize su:
Internal dilution option: Rinse water & Dilution water
Dijital çıkışlar:
Profibus DP or Modbus RTU
Doğrulama:
Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Doğruluk:
Better than 4% full scale range for standard test solutions
Drenaj:
Atmospheric pressure, vented, min. Ø 32 mm
Enerji:
230 VAC, 50/60 Hz
Max. power consumption: 240 VA
Garanti:
24 aylar
Girişimler:
Ions, e.g., antimony (III) (Sb³⁺), bismuth (III) (Bi³⁺), chloroplatinate (PtCl₆²⁻), gold (III) (Au³⁺), iron
(III) (Fe³⁺), lead (II) (Pb2+), mercury (II) (Hg2+), metavanadate (VO₃⁻) and silver (I) (Ag+) can cause
precipitation with nitrate. Copper (Cu2+) ions can decompose the diazonium salt and cause a low
result. NCl3 can cause a red color. Strong oxidizing agents interfere.
Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Kalibrasyon:
Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Koruma sınıfı:
IP44
Malzeme:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Model:
EZ2729sc
Numune akışı sayısı:
Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Numune basıncı:
By external overflow vessel (open to atmospheric pressure)
Numune kalitesi:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Numune sıcaklığı:
10 - 30 °C
Ölçüm aralığı:
Internal Dilution
0.25 - 10 mg/L TN
0.5 - 20 mg/L TN
1.25 - 50 mg/L TN
2.5 - 100 mg/L TN
Ölçüm metodu:
Colorimetric
NEDD colorimetric method after reduction with hydrazine
Ölçüm süresi:
Default: 45 min.
Continuous: 36 min.
Ortam sıcaklığı:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Otomatik temizleme:
Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Parametre:
Nitrogen, Total
Reaktif gereksinimi:
Keep reducting and colour solution refrigerated: 10 - 15 °C. All other reagents between 10 - 30 °C
Röleler:
5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
Saptama limiti:
0,25 - 10 mg/L TN: 0,25 mg/L
0,5 - 20 mg/L TN: 0,5 mg/L
1,25 - 50 mg/L TN: 1,25 mg/L
2,5 - 100 mg/L TN: 2,5 mg/L
Sertifikalar:
CE, ETL certified to UL and CSA safety standards, UKCA
Soğutma suyu:
Flow rate approx. 5 L/h; temperature max. 30 °C; pressure max. 0.5 bar
Toprak bağlantısı:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²